The ATP Fluorescence Detector is a device for the rapid detection of microbial contamination, assessing the microbial content of a sample by measuring the fluorescence intensity of adenosine triphosphate (ATP), which is present in all living cells at a level proportional to the number of living cells. During the test, the reagent reacts with ATP to produce fluorescence, and the instrument indirectly reflects the degree of microbial contamination by detecting the fluorescence intensity. The equipment is widely used in food, medicine, environmental monitoring and other fields, with rapid, sensitive, easy to operate.Protect your health anytime, anywhere with this ATP Fluorescence Detector!
Specification
Display | 3.5-inch High-precision Graphic Touch Screen |
Processor | 32-bit High-speed Data Processing Chip |
Detection accuracy | 1 × 10-18mol |
Coliform | 1 – 106cfu |
Detection Range | 0 -99999 RLUs |
Detection Time | 15 Seconds |
Detection of interferences | ±5 % or ±5 RLUs |
Operating Humidity Range | 20 – 85 % |
Operating Temperature Range | 5℃ – 40℃ |
Detection Mode | RLU and Coliform Screening |
Instrument size | 188 mm×77mm×37mm |
Standby state (20℃) | 6 months |
Charging Method | Rechargeable lithium battery, no battery replacement |
USB Interface | Equipped with a mini USB port for uploading results to a computer |
Why Choose the ATP Bacteria Detector?
- Practicality
Upper and lower limit values can be set according to the environmental testing needs to achieve rapid data assessment and early warning, rapid screening of surface cleanliness. - High sensitivity
1 × 10-18mol sensitivity - Fast speed
Conventional culture method 18-24h or more, while ATP only need more than ten seconds. - Feasibility
There is a clear correlation between the number of microorganisms and the ATP contained in the microorganisms. The number of microorganisms in the reaction can be derived indirectly by measuring the ATP content. - Operability
Traditional incubation methods are operated in the laboratory by trained technicians, whereas the ATP Rapid Cleanliness Test is very easy to operate and can be operated on-site by general staff with simple training. - Better Experience
The flexible plug-and-play design of the test tube allows for regular cleaning and long-term use, extending the life of the instrument.
If you are struggling with cleaning issues in your life, then this Atp Fluorescence Detector is for you!
Key Features

Upgrade Swab Accurate Detection
Fast detection, easy operation, reproducible reaction results, more reliable and environmentally friendly design. There are two types of swabs, solid surface swabs and water quality swabs, which can be purchased separately after use.

Top Cover Rotate 120°
The two-degree opening and closing mechanism combines both high aesthetic appeal and functional strength, safeguarding the test tube while enhancing data observation convenience.

Swab Cannula Washable
The test sleeve utilizes a plug-in design, allowing for easy regular cleaning and extending the instrument’s lifespan.

HD Touch Screen
The 3.5-inch touch interface offers an intuitive and convenient user experience, enhancing usability and intelligence.

Freely Set Upper and Lower Limit Values
By default, the upper limit value of the instrument is 999 and the lower limit value is 99, which is suitable for supermarkets, cafeterias and other Non-medical organizations. If it is a professional medical environment with higher requirements, you can set the upper limit value to 30 and the lower limit value to 10.Customers can set it according to their personal situation

User Friendly Operation
Unlike traditional cultivation methods that demand trained technicians in a lab setting, our upgraded ATP rapid detection system offers simplicity and ease of use. It requires only basic training for on-site operation by regular staff. It can swiftly deliver results in just 15 seconds and undergoes automatic calibration within 30 seconds.

Large Capacity Lithium Battery
Large-capacity lithium battery that can run for over 12 hours without stopping. It also has an impressive standby time of up to 300 hours. You can power it up with solar chargers, mobile charging banks, or car chargers for added convenience.

Aluminum alloy carrying case
Integrated case design to protect the instrument, more convenient for mobile testing.

Power button
The power button is clear and concise. Long press this button to turn on and off the machine. The operation is simple
Charging port
The product is equipped with a charging port located on the top of the device, which supports fast charging and data transmission. The overall design is simple and beautiful.

U disk record
Specific steps for saving data:
1.Use the data cable to connect the tester to the computer, connect the USB disk to the computer
2.Open the u-disk and double-click CH341SER to install the driver.
3.After successful installation, go back to the desktop of the computer, right-click on the computer, select Manage, click on Device Manager, and memorize the corresponding port name.
4.Open the ATP – PC software on the USB flash drive.
5.Select the corresponding port name in the communication window, click inquire, after the data appears, you can click export excel.
Product Features
- This atp rapid tester is made of special sealing material to enhance the light avoidance, and the test results are more stable.
- Simple interface, easy to operate.
- Bottom detection, not subject to the influence of the instrument handheld or placed at an angle, the detection data without interference, the results are more stable.
- The integrated case design makes it convenient to travel and carry.
- Low background value is favorable for the detection of trace ATP.
- Good reproducibility, providing users with more reliable and accurate data.
User Guidance
The procedure is as follows, nine steps in total
- Press the button on the left side of the instrument and the home screen appears after 30s of power-on calibration.
- Turn on the machine, click the test, the instrument prompts “put swabs” into the testing interface.
- Take out the swab from the refrigerator, leave it for 10~15 minutes and use it after it returns to room temperature.
- Take out the swab from the casing, pinch the connector with one hand, wipe the surface of the object at a 45°tilt, 10X10CM surface.
- Insert the collector back into the sleeve.
- Squeeze the connector with one hand,squeeze the upper part of the capsule with the other hand and bend it back and forth until the valve is broken.
- Squeeze the swab head 3 times so that all the liquid in the swab head is squeezed out.
- Squeeze the swab head and flick the swab downward 5 times and immediately insert the swab into the instrument for testing.
- Click Test (as shown on the left), and the test result will be available after 15s. (Save the result manually)
Test results
The test results are divided into three categories
- Test data ≤ lower limit value, the result will display “ok”
- Test data > lower limit value ≤ upper limit value, the result will display “!”
- Test data > upper limit value, the result will display “—”
caveat
- After removing the swabs from the freezer, leave them at room temperature for about 5 minutes.
- After sampling, the swab test tube can be left in a dark place for about 4 hours.
- Do not touch the swab or swab stick with your hands.
- After the reaction of the cartridge solution in the swab test tube, it should be placed in the fluorometer and read within 15 seconds.
- The swab solution has been diluted and is safe to use on food surfaces.
Factory Photography

Clean and clear office environment

Standardized manufacturing plant

Honor Certificate Display Wall
Application

Machine Surface

Medical and Heath

Personal Hygiene

Food

Canteen Tableware

Restaurant
Wide range of applications, commonly used in bacterial microbial detection, medicine and health, food safety, market law enforcement, surface cleanliness testing, medical epidemic prevention, water quality and water policy, production line hygiene, industrial water treatment, environmental protection testing, customs and entry-exit quarantine and other law enforcement departments and other industries.
Packing List

ATP Device

Suitcase

Software

Provide According Your Country Charger

Data Cable